            HOME>PRODUCTS>Atomic Spectrometer>AA990 AAS

            AA990 Atomic Spectrophotometer

            The AA900 Atomic Absorption Spectrometer is a versatile entry level instrument with a computer controlled Air/Acetylene flame for general laboratory requirements.

            Due to its high sensitivity and excellent performance, the instrument can be used for a wide range of applications including: 


            - Agriculture                  - Clinical                    -Environmental                   - Metal

            - Food                           - Mining                     -Geological                         - Petrochemical

            - Pharmaceutical           


            The versatile instrument is available in three configurations:

            AA990F    - Flame atomizer only

            AA990G    - Graphite furnace atomizer only 

            AA990FG  - Combined with flame and graphite furnace atomizer switch aromatically 


             Easy-to-use software

               - Automatic positioning and optimization of each hollow cathode lamp

               -  Control the fuel gas flows of the burner to optimize the best analytical.     Parameters

            -  Control the Czerny – Turner Monochromator

            -  Locate the wavelength and select the peak

            -  Control the electronic parameters of the photomultiplier tube detector and hollow cathode lamp current 

            -  Balance the absorbance and background energy

            -  Control the ignition of the flame

            -  Optimize the best heating program

             Integrated safety precautions for user protection by following:

               -  Burner Switch

               -  Flame Sensor

               -  Gas leak Sensor

               -  Drain Trap Sensor

               -  Power Loss Protection

               -  Circulation Water (graphite)

               -  Over Temperature Sensor (graphite)

             Precision accuracy with integrated correction system

             Life cycle value, best choice for less than 8 elements of analysis.





             AA990F / AA990G / AA990FG

            Spectrometer System
            Wavelength range190-900 nm
            Light sourceHCL & Deuterium Lamp
            Monochromator
            Grating 1800 grooves/mm
            Spectral bandwidth 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm with automatic changeover
            Scan modeAutomatic
            Optical systemSingle beam
            Wavelength accuracy±0.15 nm
            Wavelength resolution0.2 nm±0.02 nm
            Wavelength reproducibility<0.15 nm
            Baseline stability0.004 Abs/30 min
            Background correction

            Deuterium Arc & Self Reversal

            Flame Analysis
            Flame typeAir/acetylene
            Sensitivity (Cu)2 μg/ml Absorption>0.280 Abs
            Characteristic ConcentrationCu<0.04 μg/ml
            Detection limitCu<0.006 μg/ml
            RepeatabilityCu<1.0 %
            Burner headTitanium alloy
            Nebulizer 

            High–efficiency glass / acid proof 

            Pre-mix chamberCorrosion resistant
            Graphite Furnace Analysis
            Graphite head Transversal heating
            Temperature rangeAmbient-2650 ℃
            Heating program

            Up to 10 steps. Drying, Ashing,

             Atomization, Cleaning 

            Feedback Voltage and optical temperature control feedback
            Sensitivity (Cu)50 ng/m Absorption>0.40 Abs
            Detection limit Cd<0.01 ng/ml
            Repeatability

            Cu<3.0%, Cd<4.0%

            Graphite tubesPyrolytically coated with platform
            Sample sizeUp to 20μl
            Graphite coolingWater circulator available
            Data Processing
            Operating programAA Win software
            Analytical methods

            Flame AA/ Flame AE/Graphite Furnace/Hydride Generation

            Readout Modepeak height, peak area
            CalibrationsMulti-standard calibration, standard addition, interpolation
            Data storage & print out

            parameters, data, spectra &

             calibration curves

            Power Requirements
            Main unit 220 VAC 50/60 Hz  200 W
            Graphite power supply

            380 VAC 50/60 Hz  7000W

            Dimensions
            Main unit

            1100 * 500 * 450 mm / 75kg

            Graphite power supply

            500 * 500 * 50 mm / 70kg

            澳门新葡亰网站8814go客户端 <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <文本链> <文本链> <文本链> <文本链> <文本链> <文本链>