            HOME>PRODUCTS>Chromatograph>G5 Gas Chromatograph

            G5 Gas Chromatograph

            Adhering to the business philosophy of PERSEE and based on decades of R & D experience, your trusted partner the new generation gas chromatograph G5 with new intelligent electrical control system, professional high sensitivity detector and full range of application solutions has been launched.


            ◆ Stability

            The double adjustment design of voltage-stabilizing valve and stable-flow valve or needle valve is used in the pneumatic system. The use of Digital scale knob achieves the characteristics of high precision, good repeatability, convenient and intuitive flow adjustment


            ◆ Accurate

            The stable gas flow and temperature control combined with high sensitivity detector bring you more accurate qualitative and quantitative analysis results

                

            ◆ Intelligent

            The computer-controlled system, large-screen LCD display, multiple temperature protection and data network transmission make it possible to realize the laboratory digital management


            ◆ Powerful

            Different configuration of optional injectors and detectors can meet a variety of analysis needs. Anti-control software can realize more excellent expansion of configuration, and it is convenient, time-saving and labor-saving


            ◆ Injector

            Packed column injector and capillary split / splitless injector are optional. Available for the installation of a variety of columns (stainless steel columns, glass columns, capillary columns), can realize the perfect combination of 5 kinds of injections and can load up to three kinds of injectors simultaneously


            ◆ Detector

            Six kinds of high-performance detectors are optional, namely FID, TCD, FPD, NPD, ECD and PID. Three detectors can be installed simultaneously. It is very easy to install additional detectors after purchasing the equipment

            Temperature control
            Temperature range7 ℃ above room temperature (R.T.) ~ 400 ℃ (1 ℃ increment)
            Temperature control itemsOven, front / rear detector, front / rear injector, auxiliary, 6 parts in total
            Temperature programming7-stages temperature programming (Anti-control software supports 10 - stages temperature programming)
            Temperature programmed rate setting0.1 ℃~ 40 ℃/min (0.1 ℃ increment, measured at 200 ℃)
            Hydrogen Flame Ionization Detector(FID)
            Detection Limit≤7×10-12 g/s (n-hexadecane)
            Noise ≤ 2×10-13 A
            Drift≤ 4×10-13 A/30 min
            Linear range 107
            Thermal Conductivity Detector (TCD)
            Sensitivity≥ 6000 mV·mL/mg (Benzene)
            Noise≤ 0.04 mV
            Drift

            ≤ 0.2 mV/ 30min

            Linear range104
            Flame Photometric Detector (FPD)
            Detection Limit≤8×10-13 g/s (P) (Parathion-methyl)
            Linear range104
            Detection Limit≤8×10-11 g/s (S) (Parathion-methyl)
            Linear range103
            Noise≤ 4×10-13 A
            Drift≤ 1×10-12 A/30 min
            Nitrogen and phosphorus detector (NPD)
            Detection Limit≤5×10-13 g/s (N) (Azobenzen)
            Linear range103
            Detection Limit≤5×10-14 g/s (P)(Malathion)
            Linear range103
            Noise
            ≤ 2×10-13 A
            Drift
            ≤ 1×10-12 A/30 min
            澳门新葡亰网站8814go客户端 <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <蜘蛛词>| <文本链> <文本链> <文本链> <文本链> <文本链> <文本链>